Containerized Liquid-Cooling Data Center for AI & HPC

A factory-integrated modular data center with hybrid air/liquid cooling, built to run dense GPU and HPC clusters at up to 100 kW per rack.

ab32,911,310.00 ฿
Thailand (THB)

Währung ändern

Die Währung der Preise richtet sich nach dem Land. Wählen Sie ein Land, um sie zu wechseln.

Sonderanfertigung
Nach Ihren Vorgaben gefertigt: Sie wählen Größe und Ausführung.

A containerized liquid-cooling data center packs the power, cooling, backup and fire protection of a full server hall into a pre-integrated enclosure that ships as one unit. It is built for AI training, GPU inference and HPC supercomputing — workloads that push past what air cooling alone can carry. Each rack supports up to 100 kW of IT load, cooled by a hybrid system that combines cold-plate liquid cooling with air handling.

The cooling loop runs through a built-in distribution network of pipelines, manifolds and sensors, paired with a water chiller and plate heat exchanger that uses free cooling where the climate allows. Heat is rejected through a cooling tower rather than dumped back into the room. Power stays up through UPS redundancy configured as 2N or N+1, with a lithium battery bank giving roughly 10 minutes of autonomy to cover generator start or an orderly shutdown.

Fire safety uses Novec 1230 clean-agent suppression with VESDA early smoke detection, so a fault is caught before it reaches the hardware. Because major systems are tested at the factory before shipment, deployment on site is faster and more predictable than a stick-built room, and the design scales — multiple modules cluster together as compute demand grows.

  • Up to 100 kW per rack with hybrid air/liquid cold-plate cooling
  • 2N or N+1 UPS redundancy with a 10-minute lithium battery reserve
  • Novec 1230 clean-agent suppression and VESDA smoke detection
  • Factory pre-integrated and pre-tested; enclosure and IT capacity customizable

Technische Daten

Material
SPCC cold-rolled steel
Zertifizierungen
CE
Individualisierung
Enclosure size, IT capacity and configuration built to order
Cabinet standard
International Standard
Power density
100 kW/rack
Cooling
Hybrid air/liquid cold-plate; water chiller + plate heat exchanger with free cooling
Heat rejection
Cooling tower
UPS redundancy
2N or N+1
Battery backup
10-min autonomy (lithium battery)
Fire safety
Novec 1230 clean-agent suppression & VESDA smoke detection
Deployment
Factory pre-integrated and pre-tested
Scalability
Multi-module cluster expansion

Häufig gestellte Fragen

What cooling does this data center use for high-density racks?

It runs a hybrid air/liquid system. Cold-plate liquid cooling handles the dense GPU and HPC hardware, backed by a water chiller and plate heat exchanger with free cooling, and heat is rejected through a cooling tower. A built-in distribution network of pipelines, manifolds and sensors manages the loop, supporting up to 100 kW per rack.

How much IT power can each rack support?

Each rack supports up to 100 kW of IT load under the liquid-cooling configuration, which is what makes it suitable for AI training, GPU inference and HPC supercomputing clusters that exceed the limits of air cooling alone.

What keeps the servers running during a power loss?

Power is held through UPS redundancy configured as either 2N or N+1, paired with a lithium battery bank that gives roughly 10 minutes of autonomy — enough to cover a generator start or an orderly shutdown.

How is fire handled inside the enclosure?

The module uses Novec 1230 clean-agent suppression with VESDA aspirating smoke detection. VESDA catches smoke at a very early stage, and Novec 1230 extinguishes without water or residue, so it protects the electronics rather than damaging them.

Can the system be expanded as compute demand grows?

Yes. Multiple modules deploy together as a cluster for added capacity, and the enclosure size, IT capacity and internal configuration are built to order for the specific deployment.

How quickly can the unit be deployed on site?

Major systems are integrated and tested at the factory before shipment, so the unit arrives as a pre-validated solution. That makes installation faster and more predictable than building a conventional server room on site.

Ist der Versand im Preis enthalten?

Bei vorrätigen Artikeln, also allem, was Sie zur Spezifikation hinzufügen können, ist der Versand im angegebenen Preis enthalten. Bei Artikeln, die auf Bestellung gefertigt werden, ist die Lieferung entweder kostenlos (auf der Produktseite vermerkt) oder wird bei der Bestellung nach Zielort und Volumen berechnet.

Wie lange dauert die Lieferung?

Vorrätige Artikel kommen in der Regel innerhalb von ein bis drei Wochen an. Auf Bestellung gefertigte Artikel brauchen drei bis sechs Wochen: Wir arbeiten direkt mit den Herstellern, und Produktion und Logistik brauchen vor dem Versand ihre Zeit. Nach Ihrer Bestellung nennt Ihnen Ihr Ansprechpartner einen genaueren Termin. Für Verzögerungen bei der Zollabfertigung im Zielland können wir keine Haftung übernehmen.

Sind Einfuhrzölle und Steuern enthalten?

In den meisten Fällen ja. Wir liefern möglichst nach DDP (Delivered Duty Paid): Zölle und Einfuhrsteuern sind dann erledigt, und bei der Zustellung fallen für Sie keine weiteren Kosten an. In seltenen Fällen liefern wir nach DDU (Delivered Duty Unpaid); dann begleichen Sie die Einfuhrabgaben direkt beim Spediteur, aber nur, wenn das vorher mit Ihnen vereinbart wurde.

Gibt es auf Ihre Produkte eine Garantie?

Ja. Für die meisten Geräte gilt eine Herstellergarantie von ein bis zwei Jahren auf Fabrikationsfehler und technische Defekte bei normalem Gebrauch; die genaue Dauer steht auf jeder Produktseite. Tritt ein Defekt auf, organisieren wir Ersatz oder Erstattung gemäß unserer Umtausch- und Rückgaberichtlinie, und unser Team begleitet Sie Schritt für Schritt durch die Reklamation.

Angebot anfordern