{"product_id":"liquid-to-liquid-coolant-distribution-unit-cdu-for-ai-data","title":"Liquid-to-Liquid Coolant Distribution Unit (CDU) for AI Data Centers — 1000–1500 kW","description":"\u003cp\u003eA liquid-to-liquid coolant distribution unit sits between your facility chilled-water supply and the direct-to-chip cold plates cooling a GPU cluster. It keeps the two loops hydraulically separate: facility water stays on the primary side, a clean deionized-water (or glycol) loop circulates to the racks, and a brazed-plate SUS316 heat exchanger passes the heat across with an approach of under 2 °C. The result is tight, isolated control of what actually reaches the silicon — temperature held to ±0.2 to ±0.5 °C — without exposing sensitive cold plates to raw facility water chemistry.\u003c\/p\u003e\u003cp\u003eThis unit is built for the heat loads that H100, B200 and GB200 racks now put on a room. Cooling capacity runs 1000–1500 kW on the liquid-to-liquid models, enough to carry roughly eight to ten racks at 100 kW each, or fewer at NVL72 densities near 200 kW per rack. Exact rack count depends on your ΔT, coolant choice and redundancy level, so size it against a real rack layout rather than a nameplate number.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant, serviceable pumps:\u003c\/strong\u003e N+X configuration with VFD control, hot-swappable modules and dual A+B power feeds — a failed pump is isolated and replaced while the rest carry the load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeak detection as standard:\u003c\/strong\u003e cable-type sensing, spot sensors and a dew-point monitor, so moisture is caught before it reaches a rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding-management integration:\u003c\/strong\u003e SNMP, Modbus RTU and TCP, BACnet and Redfish, driven from a 10-inch color touchscreen HMI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiltration matched to the loop:\u003c\/strong\u003e 50 µm on the secondary side with SUS304 piping, 500 µm on the primary side.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eIt accepts deionized water, 25% propylene glycol for freeze protection, or fluorinated liquids, and ships indoor-rated at IP20 with an optional outdoor IP54 build. Backed by a 1-year manufacturer warranty.\u003c\/p\u003e","brand":"BarEquip.Pro","offers":[{"title":"Default Title","offer_id":67995478229091,"sku":"BEP-0956","price":311809.0,"currency_code":"THB","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/6726\/3843\/files\/ef187aae-f578-469d-9c25-a683e9f13afb.png?v=1795425297","url":"https:\/\/barequip.pro\/products\/liquid-to-liquid-coolant-distribution-unit-cdu-for-ai-data","provider":"BarEquip.Pro","version":"1.0","type":"link"}