Liquid-to-Liquid Coolant Distribution Unit (CDU) for AI Data Centers — 1000–1500 kW

A liquid-to-liquid CDU that isolates the facility chilled-water loop from direct-to-chip GPU cold plates, holding coolant temperature to ±0.2 °C across 1000–1500 kW racks.

A partir de311,757.00 ฿
Tailândia (THB)

Alterar moeda

A moeda dos preços depende do país. Escolha um país para trocá-la.

Pedido personalizado
Feito sob medida para os seus requisitos. Você escolhe o tamanho e a configuração.

A liquid-to-liquid coolant distribution unit sits between your facility chilled-water supply and the direct-to-chip cold plates cooling a GPU cluster. It keeps the two loops hydraulically separate: facility water stays on the primary side, a clean deionized-water (or glycol) loop circulates to the racks, and a brazed-plate SUS316 heat exchanger passes the heat across with an approach of under 2 °C. The result is tight, isolated control of what actually reaches the silicon — temperature held to ±0.2 to ±0.5 °C — without exposing sensitive cold plates to raw facility water chemistry.

This unit is built for the heat loads that H100, B200 and GB200 racks now put on a room. Cooling capacity runs 1000–1500 kW on the liquid-to-liquid models, enough to carry roughly eight to ten racks at 100 kW each, or fewer at NVL72 densities near 200 kW per rack. Exact rack count depends on your ΔT, coolant choice and redundancy level, so size it against a real rack layout rather than a nameplate number.

  • Redundant, serviceable pumps: N+X configuration with VFD control, hot-swappable modules and dual A+B power feeds — a failed pump is isolated and replaced while the rest carry the load.
  • Leak detection as standard: cable-type sensing, spot sensors and a dew-point monitor, so moisture is caught before it reaches a rack.
  • Building-management integration: SNMP, Modbus RTU and TCP, BACnet and Redfish, driven from a 10-inch color touchscreen HMI.
  • Filtration matched to the loop: 50 µm on the secondary side with SUS304 piping, 500 µm on the primary side.

It accepts deionized water, 25% propylene glycol for freeze protection, or fluorinated liquids, and ships indoor-rated at IP20 with an optional outdoor IP54 build. Backed by a 1-year manufacturer warranty.

Ficha técnica

Material
SUS316 brazed-plate heat exchanger, SUS304 secondary piping
Peso
625.0 kg
Tensão
Dual power feed A+B
Garantia
1 Year
Cooling capacity
1000-1500 kW
Secondary side flow rate
1000-1500 LPM
Heat exchanger
Brazed plate, SUS316, approach < 2 °C
Pump configuration
N+X redundant, VFD, hot-swappable, dual power A+B
Temperature control accuracy
±0.2 to ±0.5 °C
Secondary side filtration
50 µm
Primary side filtration
500 µm
Supported coolant
Deionized water / 25% propylene glycol / fluorinated liquid
Leak detection
Cable type + spot sensor + dew point monitor
Communication protocols
SNMP / Modbus RTU & TCP / BACnet / Redfish
HMI
10-inch color touchscreen
Protection class
Indoor IP20 / optional outdoor IP54
Application
AI data center, HPC, GPU cluster, hyperscale, legacy DC retrofit

Perguntas frequentes

Should I choose a liquid-to-liquid or liquid-to-air CDU?

Pick liquid-to-liquid if your data center already has chilled water, which most hyperscale and enterprise sites do — it runs at higher efficiency and contributes less to PUE. Choose liquid-to-air only when there is no chilled-water loop, such as an older enterprise room or an edge site, since it rejects heat straight to air. This listing is the liquid-to-liquid unit at 1000-1500 kW.

Which GPU racks does this CDU support?

The liquid-to-liquid unit is validated with NVIDIA H100, B200 and GB200 direct-to-chip cold plates, including GB200 NVL72 loops. It also runs with third-party cold plates as long as the supply manifold specs match, so share your manifold details and the coolant you intend to use.

How many racks can one 1000 kW CDU serve?

As a rough guide, a 1000 kW unit carries about eight to ten racks at 100 kW per rack, or roughly four to five racks at NVL72 densities near 200 kW per rack. The exact count depends on your ΔT, coolant type and redundancy level — send a rack layout to get a sized configuration sheet.

Can a pump be replaced without shutting the unit down?

Yes. The pumps are arranged N+X with VFD control and dual A+B power, and each module is hot-swappable. A failed pump is isolated and replaced while the remaining pumps keep carrying the cooling load, so the GPU loop stays running.

Which coolants work with this unit?

Deionized water is the most common choice for AI loads, 25% propylene glycol adds freeze protection in colder climates, and fluorinated liquids cover immersion-migration scenarios. Specify your coolant when ordering — the filter mesh and material spec are set to match it.

Can this CDU connect to our building management system?

Yes. It exposes SNMP, Modbus RTU and TCP, BACnet and Redfish, so it integrates with standard BMS and DCIM platforms. Local operation runs from a 10-inch color touchscreen HMI on the unit itself.

O frete está incluído no preço?

Nos itens em estoque, ou seja, tudo o que dá para adicionar à especificação, o frete já está no preço anunciado. Nos itens feitos sob encomenda, a entrega é grátis (isso aparece na página do produto) ou calculada no pedido, conforme o destino e o volume.

Quanto tempo leva a entrega?

Um item em estoque costuma chegar em uma a três semanas; um item sob encomenda leva de três a seis, porque trabalhamos direto com os fabricantes e a produção e a logística precisam de tempo antes do envio. Depois do pedido, o gerente responsável pela sua conta confirma um prazo mais preciso. Atrasos no desembaraço aduaneiro do país de destino não são de nossa responsabilidade.

Os impostos e taxas de importação estão incluídos?

Na maioria dos casos, sim. Enviamos de preferência no regime DDP (Delivered Duty Paid): os impostos e as taxas de importação já ficam resolvidos e você não paga nada a mais na entrega. Em casos raros o envio pode ser DDU (Delivered Duty Unpaid), e aí você acerta as taxas de importação direto com a transportadora, mas só se isso tiver sido combinado com você antes.

Os produtos têm garantia?

Sim. A maioria dos equipamentos tem garantia do fabricante de um a dois anos contra defeitos de fábrica e falhas técnicas em uso normal, e o prazo exato está na página de cada produto. Se aparecer um defeito, providenciamos a troca ou o reembolso conforme a nossa Política de trocas e devoluções, e a nossa equipe acompanha você em cada etapa da solicitação.

Etiquetas

Categorias

Solicitar orçamento