Containerized Liquid-Cooling Data Center for AI & HPC

A factory-integrated modular data center with hybrid air/liquid cooling, built to run dense GPU and HPC clusters at up to 100 kW per rack.

От32,916,737.00 ฿
Таиланд (THB)

Сменить валюту

Валюта цен зависит от страны. Выберите страну, чтобы сменить валюту.

Под заказ
Изготавливается под вашу спецификацию — размер и конфигурацию выбираете вы.

A containerized liquid-cooling data center packs the power, cooling, backup and fire protection of a full server hall into a pre-integrated enclosure that ships as one unit. It is built for AI training, GPU inference and HPC supercomputing — workloads that push past what air cooling alone can carry. Each rack supports up to 100 kW of IT load, cooled by a hybrid system that combines cold-plate liquid cooling with air handling.

The cooling loop runs through a built-in distribution network of pipelines, manifolds and sensors, paired with a water chiller and plate heat exchanger that uses free cooling where the climate allows. Heat is rejected through a cooling tower rather than dumped back into the room. Power stays up through UPS redundancy configured as 2N or N+1, with a lithium battery bank giving roughly 10 minutes of autonomy to cover generator start or an orderly shutdown.

Fire safety uses Novec 1230 clean-agent suppression with VESDA early smoke detection, so a fault is caught before it reaches the hardware. Because major systems are tested at the factory before shipment, deployment on site is faster and more predictable than a stick-built room, and the design scales — multiple modules cluster together as compute demand grows.

  • Up to 100 kW per rack with hybrid air/liquid cold-plate cooling
  • 2N or N+1 UPS redundancy with a 10-minute lithium battery reserve
  • Novec 1230 clean-agent suppression and VESDA smoke detection
  • Factory pre-integrated and pre-tested; enclosure and IT capacity customizable

Характеристики

Материал
SPCC cold-rolled steel
Сертификаты
CE
Кастомизация
Enclosure size, IT capacity and configuration built to order
Cabinet standard
International Standard
Power density
100 kW/rack
Cooling
Hybrid air/liquid cold-plate; water chiller + plate heat exchanger with free cooling
Heat rejection
Cooling tower
UPS redundancy
2N or N+1
Battery backup
10-min autonomy (lithium battery)
Fire safety
Novec 1230 clean-agent suppression & VESDA smoke detection
Deployment
Factory pre-integrated and pre-tested
Scalability
Multi-module cluster expansion

Частые вопросы

What cooling does this data center use for high-density racks?

It runs a hybrid air/liquid system. Cold-plate liquid cooling handles the dense GPU and HPC hardware, backed by a water chiller and plate heat exchanger with free cooling, and heat is rejected through a cooling tower. A built-in distribution network of pipelines, manifolds and sensors manages the loop, supporting up to 100 kW per rack.

How much IT power can each rack support?

Each rack supports up to 100 kW of IT load under the liquid-cooling configuration, which is what makes it suitable for AI training, GPU inference and HPC supercomputing clusters that exceed the limits of air cooling alone.

What keeps the servers running during a power loss?

Power is held through UPS redundancy configured as either 2N or N+1, paired with a lithium battery bank that gives roughly 10 minutes of autonomy — enough to cover a generator start or an orderly shutdown.

How is fire handled inside the enclosure?

The module uses Novec 1230 clean-agent suppression with VESDA aspirating smoke detection. VESDA catches smoke at a very early stage, and Novec 1230 extinguishes without water or residue, so it protects the electronics rather than damaging them.

Can the system be expanded as compute demand grows?

Yes. Multiple modules deploy together as a cluster for added capacity, and the enclosure size, IT capacity and internal configuration are built to order for the specific deployment.

How quickly can the unit be deployed on site?

Major systems are integrated and tested at the factory before shipment, so the unit arrives as a pre-validated solution. That makes installation faster and more predictable than building a conventional server room on site.

Входит ли доставка в цену?

Для позиций со склада — всё, что можно добавить в спецификацию, — доставка входит в указанную цену. Для позиций под заказ доставка либо бесплатна (это отмечено на странице товара), либо считается при оформлении заказа, исходя из направления и объёма.

Сколько занимает доставка?

Позиции со склада обычно приходят за одну-три недели. Позиции под заказ — за три-шесть недель: мы работаем напрямую с производителями, и до отгрузки нужно время на производство и логистику. Закреплённый за вами менеджер подтверждает более точный срок после оформления заказа. Обратите внимание: за задержки при таможенном оформлении в стране назначения мы не отвечаем.

Входят ли пошлины и налоги на импорт?

В большинстве случаев да — мы стремимся отгружать на условиях DDP, то есть пошлины и импортные налоги улажены, и при получении с вас не потребуют доплат. В редких случаях отгрузка идёт на условиях DDU, когда импортные платежи вы вносите перевозчику напрямую, — но только по согласованию с вами заранее.

Есть ли гарантия на оборудование?

Да. На большую часть оборудования действует гарантия производителя от года до двух: она покрывает заводской брак и технические неисправности при нормальной эксплуатации, конкретный срок указан на странице товара. Если дефект проявился, мы организуем замену или возврат средств в соответствии с нашей Политикой обмена и возврата, а наша команда проведёт вас по обращению шаг за шагом.

Запросить предложение