Liquid-to-Liquid Coolant Distribution Unit (CDU) for AI Data Centers — 1000–1500 kW

A liquid-to-liquid CDU that isolates the facility chilled-water loop from direct-to-chip GPU cold plates, holding coolant temperature to ±0.2 °C across 1000–1500 kW racks.

From311,809.00 ฿
Thailand (THB)

Change currency

Prices follow the country you buy from. Pick a country to switch the currency.

Custom order
Made to order to your spec — you choose the size and configuration.

A liquid-to-liquid coolant distribution unit sits between your facility chilled-water supply and the direct-to-chip cold plates cooling a GPU cluster. It keeps the two loops hydraulically separate: facility water stays on the primary side, a clean deionized-water (or glycol) loop circulates to the racks, and a brazed-plate SUS316 heat exchanger passes the heat across with an approach of under 2 °C. The result is tight, isolated control of what actually reaches the silicon — temperature held to ±0.2 to ±0.5 °C — without exposing sensitive cold plates to raw facility water chemistry.

This unit is built for the heat loads that H100, B200 and GB200 racks now put on a room. Cooling capacity runs 1000–1500 kW on the liquid-to-liquid models, enough to carry roughly eight to ten racks at 100 kW each, or fewer at NVL72 densities near 200 kW per rack. Exact rack count depends on your ΔT, coolant choice and redundancy level, so size it against a real rack layout rather than a nameplate number.

  • Redundant, serviceable pumps: N+X configuration with VFD control, hot-swappable modules and dual A+B power feeds — a failed pump is isolated and replaced while the rest carry the load.
  • Leak detection as standard: cable-type sensing, spot sensors and a dew-point monitor, so moisture is caught before it reaches a rack.
  • Building-management integration: SNMP, Modbus RTU and TCP, BACnet and Redfish, driven from a 10-inch color touchscreen HMI.
  • Filtration matched to the loop: 50 µm on the secondary side with SUS304 piping, 500 µm on the primary side.

It accepts deionized water, 25% propylene glycol for freeze protection, or fluorinated liquids, and ships indoor-rated at IP20 with an optional outdoor IP54 build. Backed by a 1-year manufacturer warranty.

Specifications

Material
SUS316 brazed-plate heat exchanger, SUS304 secondary piping
Weight
625.0 kg
Voltage
Dual power feed A+B
Warranty
1 Year
Cooling capacity
1000-1500 kW
Secondary side flow rate
1000-1500 LPM
Heat exchanger
Brazed plate, SUS316, approach < 2 °C
Pump configuration
N+X redundant, VFD, hot-swappable, dual power A+B
Temperature control accuracy
±0.2 to ±0.5 °C
Secondary side filtration
50 µm
Primary side filtration
500 µm
Supported coolant
Deionized water / 25% propylene glycol / fluorinated liquid
Leak detection
Cable type + spot sensor + dew point monitor
Communication protocols
SNMP / Modbus RTU & TCP / BACnet / Redfish
HMI
10-inch color touchscreen
Protection class
Indoor IP20 / optional outdoor IP54
Application
AI data center, HPC, GPU cluster, hyperscale, legacy DC retrofit

Frequently asked questions

Should I choose a liquid-to-liquid or liquid-to-air CDU?

Pick liquid-to-liquid if your data center already has chilled water, which most hyperscale and enterprise sites do — it runs at higher efficiency and contributes less to PUE. Choose liquid-to-air only when there is no chilled-water loop, such as an older enterprise room or an edge site, since it rejects heat straight to air. This listing is the liquid-to-liquid unit at 1000-1500 kW.

Which GPU racks does this CDU support?

The liquid-to-liquid unit is validated with NVIDIA H100, B200 and GB200 direct-to-chip cold plates, including GB200 NVL72 loops. It also runs with third-party cold plates as long as the supply manifold specs match, so share your manifold details and the coolant you intend to use.

How many racks can one 1000 kW CDU serve?

As a rough guide, a 1000 kW unit carries about eight to ten racks at 100 kW per rack, or roughly four to five racks at NVL72 densities near 200 kW per rack. The exact count depends on your ΔT, coolant type and redundancy level — send a rack layout to get a sized configuration sheet.

Can a pump be replaced without shutting the unit down?

Yes. The pumps are arranged N+X with VFD control and dual A+B power, and each module is hot-swappable. A failed pump is isolated and replaced while the remaining pumps keep carrying the cooling load, so the GPU loop stays running.

Which coolants work with this unit?

Deionized water is the most common choice for AI loads, 25% propylene glycol adds freeze protection in colder climates, and fluorinated liquids cover immersion-migration scenarios. Specify your coolant when ordering — the filter mesh and material spec are set to match it.

Can this CDU connect to our building management system?

Yes. It exposes SNMP, Modbus RTU and TCP, BACnet and Redfish, so it integrates with standard BMS and DCIM platforms. Local operation runs from a 10-inch color touchscreen HMI on the unit itself.

Is shipping included in the price?

For in-stock items — anything you can add to the cart — shipping is included in the listed price. For made-to-order items, delivery is either free (marked on the product page) or calculated when you place your order, based on destination and volume.

How long does delivery take?

In-stock items typically arrive within one to three weeks. Made-to-order items take three to six weeks, since we work directly with manufacturers and need time for production and logistics before shipping. Your assigned manager confirms a more precise estimate once your order is placed. Please note we can't be responsible for delays caused by customs clearance in the destination country.

Are import duties and taxes included?

In most cases, yes — we aim to ship Delivered Duty Paid (DDP), which means duties and import taxes are handled so you don't face extra charges on delivery. In rare cases we may ship Delivered Duty Unpaid (DDU), where you would settle import charges directly with the carrier — but only when agreed with you in advance.

Do your products come with a warranty?

Yes. Most of our equipment comes with a one-to-two-year manufacturer's warranty covering factory defects and technical faults under normal use; the specific term is stated on each product page. If a defect appears, we arrange a replacement or refund in line with our Exchange & Return Policy, and our team guides you through the claim step by step.