Containerized Liquid-Cooling Data Center for AI & HPC

A factory-integrated modular data center with hybrid air/liquid cooling, built to run dense GPU and HPC clusters at up to 100 kW per rack.

Desde32,916,737.00 ฿
Tailandia (THB)

Cambiar moneda

La moneda de los precios depende del país. Elija un país para cambiarla.

Pedido personalizado
Se fabrica según sus requisitos: usted elige el tamaño y la configuración.

A containerized liquid-cooling data center packs the power, cooling, backup and fire protection of a full server hall into a pre-integrated enclosure that ships as one unit. It is built for AI training, GPU inference and HPC supercomputing — workloads that push past what air cooling alone can carry. Each rack supports up to 100 kW of IT load, cooled by a hybrid system that combines cold-plate liquid cooling with air handling.

The cooling loop runs through a built-in distribution network of pipelines, manifolds and sensors, paired with a water chiller and plate heat exchanger that uses free cooling where the climate allows. Heat is rejected through a cooling tower rather than dumped back into the room. Power stays up through UPS redundancy configured as 2N or N+1, with a lithium battery bank giving roughly 10 minutes of autonomy to cover generator start or an orderly shutdown.

Fire safety uses Novec 1230 clean-agent suppression with VESDA early smoke detection, so a fault is caught before it reaches the hardware. Because major systems are tested at the factory before shipment, deployment on site is faster and more predictable than a stick-built room, and the design scales — multiple modules cluster together as compute demand grows.

  • Up to 100 kW per rack with hybrid air/liquid cold-plate cooling
  • 2N or N+1 UPS redundancy with a 10-minute lithium battery reserve
  • Novec 1230 clean-agent suppression and VESDA smoke detection
  • Factory pre-integrated and pre-tested; enclosure and IT capacity customizable

Ficha técnica

Material
SPCC cold-rolled steel
Certificaciones
CE
Personalización
Enclosure size, IT capacity and configuration built to order
Cabinet standard
International Standard
Power density
100 kW/rack
Cooling
Hybrid air/liquid cold-plate; water chiller + plate heat exchanger with free cooling
Heat rejection
Cooling tower
UPS redundancy
2N or N+1
Battery backup
10-min autonomy (lithium battery)
Fire safety
Novec 1230 clean-agent suppression & VESDA smoke detection
Deployment
Factory pre-integrated and pre-tested
Scalability
Multi-module cluster expansion

Preguntas frecuentes

What cooling does this data center use for high-density racks?

It runs a hybrid air/liquid system. Cold-plate liquid cooling handles the dense GPU and HPC hardware, backed by a water chiller and plate heat exchanger with free cooling, and heat is rejected through a cooling tower. A built-in distribution network of pipelines, manifolds and sensors manages the loop, supporting up to 100 kW per rack.

How much IT power can each rack support?

Each rack supports up to 100 kW of IT load under the liquid-cooling configuration, which is what makes it suitable for AI training, GPU inference and HPC supercomputing clusters that exceed the limits of air cooling alone.

What keeps the servers running during a power loss?

Power is held through UPS redundancy configured as either 2N or N+1, paired with a lithium battery bank that gives roughly 10 minutes of autonomy — enough to cover a generator start or an orderly shutdown.

How is fire handled inside the enclosure?

The module uses Novec 1230 clean-agent suppression with VESDA aspirating smoke detection. VESDA catches smoke at a very early stage, and Novec 1230 extinguishes without water or residue, so it protects the electronics rather than damaging them.

Can the system be expanded as compute demand grows?

Yes. Multiple modules deploy together as a cluster for added capacity, and the enclosure size, IT capacity and internal configuration are built to order for the specific deployment.

How quickly can the unit be deployed on site?

Major systems are integrated and tested at the factory before shipment, so the unit arrives as a pre-validated solution. That makes installation faster and more predictable than building a conventional server room on site.

¿El envío está incluido en el precio?

En los artículos en stock —todo lo que se puede añadir al carrito— el envío está incluido en el precio indicado. En los artículos fabricados bajo pedido, la entrega es gratuita (se indica en la ficha del producto) o se calcula al hacer el pedido según el destino y el volumen.

¿Cuánto tarda la entrega?

Los artículos en stock suelen llegar en una a tres semanas. Los fabricados bajo pedido tardan de tres a seis semanas, porque trabajamos directamente con los fabricantes y hace falta tiempo para la producción y la logística antes del envío. Su gestor asignado le confirma un plazo más preciso una vez hecho el pedido. Tenga en cuenta que no podemos responder de los retrasos debidos al despacho de aduanas en el país de destino.

¿Están incluidos los aranceles e impuestos de importación?

En la mayoría de los casos, sí: procuramos enviar con derechos pagados (DDP), es decir, los aranceles y los impuestos de importación quedan gestionados y no tendrá cargos adicionales en la entrega. En casos excepcionales podemos enviar con derechos no pagados (DDU), y entonces usted liquida los cargos de importación directamente con el transportista, pero solo si lo acordamos antes con usted.

¿Los productos tienen garantía?

Sí. La mayor parte de nuestro equipamiento tiene una garantía del fabricante de uno a dos años que cubre defectos de fábrica y averías técnicas con un uso normal; el plazo concreto figura en cada ficha de producto. Si aparece un defecto, organizamos la sustitución o el reembolso conforme a nuestra Política de cambios y devoluciones, y nuestro equipo le acompaña en la reclamación paso a paso.