Liquid-to-Air CDU Rack-Mount Cooling System for AI/GPU Clusters
A rack-mount coolant distribution unit that pulls 30–150 kW of heat off dense AI/GPU racks while holding PUE below 1.15.
Desde442,277.00 ฿
Tailandia (THB)
–
Pedido personalizado
Se fabrica según sus requisitos: usted elige el tamaño y la configuración.
A coolant distribution unit (CDU) sits between your facility water loop and the servers, moving heat out of high-density AI and GPU racks that air alone can no longer handle. This rack-mount model fits a standard rack in a 445 × 900 × 175 mm chassis and carries a cooling capacity of 30–150 kW across its variants, so a single data hall can be sized from a modest cluster up to a fully packed compute aisle.
The hydraulics run on a 1+1 pump configuration, where the second pump stands by and takes over if the first drops out — a failed pump does not mean a thermal shutdown of the rack it feeds. A built-in PLC manages the loop, and the unit targets a facility PUE under 1.15, which is where the operating-cost argument for liquid cooling usually lands.
Cooling capacity 30–150 kW, selectable by variant
1+1 redundant pump set with automatic failover
Rated power draw 0.5 kW; approach temperature difference 5 °C
Power input 90–300 Vac or 180–300 Vdc, depending on variant
PLC control, AC pump and fan motors, R-410A refrigerant circuit
Backed by a 1-year manufacturer warranty, with machinery test reports and outgoing-inspection video provided per unit.
Ficha técnica
Color
Black
Dimensiones (L × An × Al)
900 × 445 × 175 mm
Peso
50.0 kg
Potencia
500 W
Tensión
90–300 Vac / 180–300 Vdc
Garantía
1 year
Certificaciones
CE, RoHS
Personalización
OEM branding available by order volume
Unit type
Coolant Distribution Unit (CDU)
Mounting
Rack
Cooling capacity
30–150 kW
Rated power consumption
0.5 kW
Pumps
1+1 redundant
Approach temperature difference
5 °C
Secondary inlet temperature
40 °C
Refrigerant
R-410A
Control
PLC
Pump motor type
AC
Fan motor type
AC
Target PUE
< 1.15
Applicable industry
Data Center
Preguntas frecuentes
What does a CDU do in a data center?
A coolant distribution unit sits between the facility water loop and the liquid-cooled servers. It transfers rack heat into the facility loop and holds the secondary coolant at the temperature the hardware needs, which is how dense AI and GPU racks stay within thermal limits once air cooling can no longer keep up.
How much cooling capacity does this unit provide?
Capacity runs from 30 kW to 150 kW depending on the variant you choose. That range lets the same rack-mount platform cover a single dense cabinet through to a fully packed compute aisle; pick the capacity that matches your rack load when ordering.
Does the pump have redundancy if one fails?
Yes. The unit uses a 1+1 pump set: one pump runs while the second stands by and takes over automatically on a fault. A single pump failure does not interrupt coolant flow or force a thermal shutdown of the rack it feeds.
What power input does the CDU accept?
Two input options are available: 90–300 Vac single-phase, and 180–300 Vdc for DC-bus data centers. Specify the voltage form that matches your facility feed when ordering, since each is a separate variant.
Will this unit fit a standard server rack?
The chassis measures 445 × 900 × 175 mm and mounts in a standard rack. The 175 mm height keeps the footprint compact so it consumes minimal rack units while still handling up to 150 kW of heat load.
What efficiency can we expect from liquid cooling with this CDU?
The unit targets a facility PUE below 1.15, with a rated power draw of just 0.5 kW. That efficiency is the main reason operators move to liquid cooling rather than expanding air handling as rack densities climb.
¿El envío está incluido en el precio?
En los artículos en stock —todo lo que se puede añadir al carrito— el envío está incluido en el precio indicado. En los artículos fabricados bajo pedido, la entrega es gratuita (se indica en la ficha del producto) o se calcula al hacer el pedido según el destino y el volumen.
¿Cuánto tarda la entrega?
Los artículos en stock suelen llegar en una a tres semanas. Los fabricados bajo pedido tardan de tres a seis semanas, porque trabajamos directamente con los fabricantes y hace falta tiempo para la producción y la logística antes del envío. Su gestor asignado le confirma un plazo más preciso una vez hecho el pedido. Tenga en cuenta que no podemos responder de los retrasos debidos al despacho de aduanas en el país de destino.
¿Están incluidos los aranceles e impuestos de importación?
En la mayoría de los casos, sí: procuramos enviar con derechos pagados (DDP), es decir, los aranceles y los impuestos de importación quedan gestionados y no tendrá cargos adicionales en la entrega. En casos excepcionales podemos enviar con derechos no pagados (DDU), y entonces usted liquida los cargos de importación directamente con el transportista, pero solo si lo acordamos antes con usted.
¿Los productos tienen garantía?
Sí. La mayor parte de nuestro equipamiento tiene una garantía del fabricante de uno a dos años que cubre defectos de fábrica y averías técnicas con un uso normal; el plazo concreto figura en cada ficha de producto. Si aparece un defecto, organizamos la sustitución o el reembolso conforme a nuestra Política de cambios y devoluciones, y nuestro equipo le acompaña en la reclamación paso a paso.