Fixed Industrial Gas Detector — Multi-Gas (H2S, CH4, LPG, CO, O2, Cl2)

Wall-mounted multi-gas detector that monitors combustible and toxic gases with a siren alarm and three relays for industrial control systems.

11,908.00 ฿
Envío calculado aparte
Plazo de entrega: 2–4 semanas

MOQ: 10

This fixed gas detector mounts to a wall in a kitchen, plant room or process area and watches the air for combustible and toxic gases — H2S, methane (CH4), LPG, carbon monoxide (CO), chlorine (Cl2), oxygen depletion (O2), VOCs, CO2 and refrigerants among them. When a reading crosses its alarm point it drives a built-in siren and switches any of three on-board relays, so it can trip an extractor, cut a gas valve or signal a BMS without extra hardware.

It runs on a 24 V DC supply drawing under 3 W and reports over a 4–20 mA loop or RS485 power bus, which drops it straight into most control systems. Sampling is by natural diffusion, so there is no pump to service, and the IP66/IP67 stainless-steel and aluminum housing stands up to washdown and dust. An infrared remote lets a technician check parameters and recalibrate without opening the enclosure.

  • Catalytic, electrochemical and infrared sensor options cover flammable, toxic and CO2/refrigerant gases
  • Fast response: T90 ≤20s for flammable gases, ≤30s for O2/CO/H2S, ≤60s for others
  • Three relays plus 4–20 mA or RS485 output for valves, fans and alarm panels
  • IECEx and ATEX certified for hazardous-area installation

Ficha técnica

Material
Stainless Steel, Aluminum Alloy
Potencia
3 W
Tensión
DC 24V ±6V
Garantía
1 Year
Certificaciones
IECEx, ATEX
Personalización
OEM, ODM
Model
GTQ-BS03
Target gases
Combustible gas, toxic gas, O2, VOC, CO2, Freon (H2S, CH4, LPG, CO, Cl2)
Sensor type
Catalytic, electrochemical, infrared
Sampling method
Natural diffusion
Alarm mode
Siren
Relays
3
Signal output
4-20mA or RS485 power bus
Response time (flammable)
T90 ≤20 s
Response time (O2/CO/H2S)
T90 ≤30 s
Response time (other gases)
T90 ≤60 s
Alarm deviation
±3% of alarm points
Ingress protection
IP66/IP67
Accuracy class
Standard accuracy
Remote control
Infrared

Preguntas frecuentes

Which gases does this fixed detector monitor?

Depending on the sensor fitted, it detects combustible and toxic gases including hydrogen sulfide (H2S), methane (CH4), LPG, carbon monoxide (CO), chlorine (Cl2) and oxygen (O2), plus VOCs, CO2 and refrigerants. Specify the target gas when ordering so the right catalytic, electrochemical or infrared sensor is installed.

How does the detector connect to a control system?

It outputs a standard 4–20 mA current loop or communicates over an RS485 power bus, and carries three on-board relays. The relays can trip an extractor fan, close a solenoid gas valve or signal a building management system directly, while the built-in siren alerts staff on site.

Can it be installed in a hazardous area?

Yes. The unit is IECEx and ATEX certified and housed in a stainless-steel and aluminum enclosure rated IP66/IP67 against dust and water jets, so it suits washdown kitchens, plant rooms and demanding industrial environments.

What power supply does the detector need?

It runs on 24 V DC (±6 V) and draws no more than 3 W. Sampling is by natural diffusion, so there is no pump to power or maintain.

How is the detector calibrated?

An infrared remote control lets a technician check parameters and recalibrate the detector without opening the housing, which keeps the enclosure's IP66/IP67 seal intact during routine service.

How fast does it respond to a leak?

Response time is T90 ≤20 seconds for flammable gases, ≤30 seconds for oxygen, CO and H2S, and ≤60 seconds for other gases, with an alarm deviation of ±3% of the set alarm points.

¿El envío está incluido en el precio?

En los artículos en stock —todo lo que se puede añadir al carrito— el envío está incluido en el precio indicado. En los artículos fabricados bajo pedido, la entrega es gratuita (se indica en la ficha del producto) o se calcula al hacer el pedido según el destino y el volumen.

¿Cuánto tarda la entrega?

Los artículos en stock suelen llegar en una a tres semanas. Los fabricados bajo pedido tardan de tres a seis semanas, porque trabajamos directamente con los fabricantes y hace falta tiempo para la producción y la logística antes del envío. Su gestor asignado le confirma un plazo más preciso una vez hecho el pedido. Tenga en cuenta que no podemos responder de los retrasos debidos al despacho de aduanas en el país de destino.

¿Están incluidos los aranceles e impuestos de importación?

En la mayoría de los casos, sí: procuramos enviar con derechos pagados (DDP), es decir, los aranceles y los impuestos de importación quedan gestionados y no tendrá cargos adicionales en la entrega. En casos excepcionales podemos enviar con derechos no pagados (DDU), y entonces usted liquida los cargos de importación directamente con el transportista, pero solo si lo acordamos antes con usted.

¿Los productos tienen garantía?

Sí. La mayor parte de nuestro equipamiento tiene una garantía del fabricante de uno a dos años que cubre defectos de fábrica y averías técnicas con un uso normal; el plazo concreto figura en cada ficha de producto. Si aparece un defecto, organizamos la sustitución o el reembolso conforme a nuestra Política de cambios y devoluciones, y nuestro equipo le acompaña en la reclamación paso a paso.

Solicitar presupuesto